(Model No: XM101D) High Frequency Mobile X-ray Camera

Ot-Fsi Electric Gynecology Operating Table

Electric Operating Table (Model OT-DLC)

I have found results from400+products and200+suppliers aboutMobile x-ray camera price







































When assessing price points, the most critical factor is the Generator Power Output (kW); entry-level units typically offer 3.5kW to 5kW, while high-end mobile systems reach 20kW to 50kW for thicker body part imaging. You must also verify the Pixel Pitch of the Digital Radiography (DR) detector (ideally <140 μm) and the Battery Autonomy, ensuring the unit can handle at least 100-200 exposures on a single charge. Higher prices usually reflect Wireless Flat Panel Detectors (FPD) and Motorized Movement capabilities.
As medical devices emitting ionizing radiation, these units must adhere to IEC 60601-1 (General safety) and IEC 60601-2-54 (X-ray equipment safety). For market entry, ensure the supplier provides CE Marking (MDR 2017/745) for Europe or FDA 510(k) clearance for the US. Additionally, the manufacturer should hold an ISO 13485 certification, which specifically governs quality management systems for medical devices.
The detector is often the most expensive component. Amorphous Silicon (a-Si) with Cesium Iodide (CsI) scintillators are priced higher due to their superior DQE (Detective Quantum Efficiency), which allows for lower radiation doses to patients compared to Gadolinium Oxysulfide (GOS) detectors. Choosing a fixed-cable detector can reduce the initial purchase price by 15-25%, but wireless detectors are preferred for mobile scenarios to improve clinical workflow and hygiene.
For busy wards, prioritize units with Integrated Workstations that allow for immediate image preview and DICOM 3.0 compatibility for seamless integration with PACS/RIS systems. Look for Telescopic Arm designs that offer a wide range of motion for bedside imaging and Anti-collision sensors to protect both the equipment and patients during transport.
The biggest risks include Damage during transit and Regulatory seizure. X-ray tubes are fragile and sensitive to vibration; ensure the contract specifies Shockwatch and Tiltwatch indicators on packaging. To avoid customs issues, verify that the HS Code (typically 9022.14) and all radiation safety labels are correctly applied according to the destination country's laws.
Negotiate for a minimum 2-year warranty on the X-ray tube and detector. Since on-site repair is difficult for cross-border trade, insist on Remote Diagnostic Access via software and a Spare Parts Kit (including cables and fuses) to be shipped with the main unit. For large orders, request Online Technical Training for your local biomedical engineers as part of the package.
Given the high unit price, use Secured Payment services provided by reputable platforms like Made-in-China.com, which offer escrow-like protection. Avoid 100% upfront T/T payments; instead, opt for a 30% deposit and 70% balance against the Bill of Lading (B/L) or a Letter of Credit (L/C) to ensure the supplier meets all shipping and documentation requirements before receiving full payment.
Due to the precision electronics and lead shielding, Air Freight is recommended to minimize the duration of mechanical vibration, despite higher costs. If using Sea Freight, ensure the unit is packed in a Vacuum-sealed moisture-proof bag within a Fumigated wooden crate to prevent corrosion from salty sea air. Always purchase All-Risk Marine Insurance covering 110% of the CIF value.