SourcingAI

Refrigeration

I have found results from70000+products and30000+suppliers aboutRefrigeration

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Piston Refrigeration Machinery
Type: Water-Cooled
Type: Air-Cooled
Type: Display Cooler
Cabinet Air Conditioner
Compressor Car Refrigerator
Type: Chest/Deep Freezer
Tunnel Type Quick Freezer
Voltage: 380V
Sealing Method: Totally Enclosed
Cooling Mode: Air-Cooled
Cooling Water: Industrial Water
System Type: Closed System
Fans Species: Frequency Fan
Noise Level: Low
Certification: ISO
Condition: New
Door Number: Double Doors
Door Type: Folding Door
Power Source: Electricity
Temperature Control: Smart Thermostat
Temperature Type: Single-temperature
Defrost Type: Auto Defrost
Cold Storage & Freezing
Refrigerant: Freon
Size: Medium
Structure: Assembled
Use Nature: Production
Suitable for: Factory
Usage: Food
Warranty: 1-2 Years
ventilation mode: mechanical ventilation
Cooling Method: Water-cooled
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Compressor Number: 1
Application Fields: Electroplating
Application Machine: Grinder
Capacity: 301-400L
Air Tube Material: Plastics
Corrosion Durability: Ultrahigh
Operating Voltage: 230 VAC
Mounting: Wall/Window Mount
Lifetime: 15~20 years
Cabinet Type (Open Outward)
Power Supply Type: DC
Component: Compressor
Compatible Truck Type: Heavy-duty Truck
Installation Type: Roof-mounted
Temperature: -10-0℃
Internal Driving Mode
Vertical Air Supply
Control Method: Digital Panel
Sealing Method: Semi-Closed
System Type: Open System
Noise Level: Ordinary
Noise Level: 70dB
Certification: CE
Certification: RoHS
Certification: CCC
Certification: CB
Certification: EMC
Certification: GS
Certification: ETL
Certification: TUV
Certification: ISO9001
Certification: ROHS
Certification: UR
Door Type: Swing Door
Door Type: Sliding Door
Power Source: Diesel Engine
Temperature Control: Mechanical Thermostat
Temperature Type: Double-temperature
Defrost Type: Manual Defrost
Function: Freezing
Function: Cold Storage
Refrigerant: R404A
Size: Large
Structure: Civil Construction
Use Nature: Distribution
Usage: Blood
Usage: Medicine
Warranty: 5 Years
Cooling Method: Air-cooled
Application Fields: Mechanical Engineering
Application Fields: Food Processing
Application Fields: Plastic
CNC Machine Tools

Sourcing guidance for Refrigeration

What are the key technical specifications to consider when selecting a refrigeration system?

Buyers must prioritize the Cooling Capacity (BTU/h or kW) to ensure it meets the heat load requirements of the specific application. Key components to verify include the compressor brand (e.g., Bitzer, Copeland, or Danfoss) for reliability, and the refrigerant type (e.g., R404A, R448A, or CO2) to ensure compliance with local environmental regulations. Additionally, evaluate the Energy Efficiency Ratio (EER) or Coefficient of Performance (COP) to minimize long-term operational costs.

Which international compliance standards are mandatory for refrigeration equipment?

For the North American market, look for UL (Underwriters Laboratories) or ETL certifications. For the European market, CE marking and compliance with the Pressure Equipment Directive (PED) are essential. Furthermore, ensure the equipment meets ISO 9001 for manufacturing quality and RoHS/REACH for hazardous substance restrictions. If the equipment is for food storage, NSF (National Sanitation Foundation) standards are often required.

How do I determine the economic feasibility of a high-end refrigeration unit?

Perform a Total Cost of Ownership (TCO) analysis. This includes the initial purchase price, shipping and installation costs, and projected energy consumption over 5-10 years. Investing in Inverter Technology may have a higher upfront cost but can reduce energy bills by 20-40%, making it more economically viable for long-term commercial use.

What usage scenarios require specialized refrigeration configurations?

For Cold Chain Logistics, systems must include redundant compressors and remote monitoring IoT modules to prevent cargo loss. In Medical/Laboratory settings, precise temperature stability (±0.1°C) and alarm systems for power failure are critical. For Industrial Processing, look for explosion-proof ratings if the unit is placed near volatile chemicals.

Cross-Border Procurement Strategy for Refrigeration Equipment

What are the primary risks when importing large-scale refrigeration units?

The biggest risks include damage during transit and non-compliance with local voltage/frequency (e.g., 60Hz vs 50Hz). To mitigate this, require the supplier to use seaworthy reinforced wooden crate packaging and provide a Pre-Shipment Inspection (PSI) report. Always confirm the electrical configuration matches your local grid before production begins.

How should I negotiate with suppliers on Made-in-China.com?

Focus on warranty terms and spare parts. Negotiate for a 1-2% free spare parts kit (including sensors, controllers, and gaskets) to be included in the shipment. Ask for tiered pricing based on annual volume rather than a single order, and request video factory audits to verify their production capacity and testing labs.

What are the best practices for shipping and logistics to ensure equipment safety?

Due to the weight and sensitivity of compressors, use FCL (Full Container Load) rather than LCL to reduce handling. Ensure the contract specifies Incoterms 2020 (e.g., CIF or DAP) clearly. It is vital to purchase Marine Insurance that covers 'All Risks' to protect against mechanical derangement during sea voyages.

How can I ensure transaction security for high-value industrial orders?

Utilize Secured Trading Services offered by Made-in-China.com to ensure payments are only released upon milestone achievements. Use a 30% deposit and 70% balance payment structure, where the balance is paid only after receiving a third-party quality inspection certificate (such as SGS or Intertek).

Related queries