Oxygen probe
I have found results from20000+products and5000+suppliers aboutOxygen probe
Industrial Online Cod Sensor Water Quality Chemical Oxygen Demand Probe
Boqu Dog 209fa Hot Sell Industrial Dissolved Oxygen Sensor Do Probe
Renke Farming Aquaculture River Freshwater Do Meter Optical Dissolved Oxygen Probe
Advanced Oxygen Potential Measuring Probe for Reliable O2 Control Analyzer Measurement Devices
Advanced Oxygen Measuring Probe Meter for Accurate O2 Monitoring
Metallurgical Oxygen Sensors Thermocouple Manufacturer Accessories Hydrogen Measurement Probe
Fast Thermocouple Immersion Sensor Manufacturer R/S/B Oxygen Measurement Probe for Steel Plant
Firstrate FST100-DO106 Dissolved Oxygen Dissolved Oxygen Conductivity Probe Graphite EC Conductivity
FST100-DO106 Smart Fluorescent Dissolved Oxygen Analyzer Probe
Durable Hdo100 High-Temperature Dissolved Oxygen Probe for Bioreactors
Durable Constant Oxygen Probe for Industrial and Laboratory Use
Most Common Do Models Dissolved Oxygen Probe Two Installation Methods
High-Precision Oxygen Measurement Probe for Reliable O2 Detection
Precision Oxygen Measurement Probe for Reliable O2 Testing
Fuanshi Industrial High Precision Electrochemical Type K Oxygen Meter Probe
High-Precision Oxygen Sensor Probe for Superior Water Quality
Industrial Do Probe with Automatic Temperature Compensation and Dissolved Oxygen Electrode
Nobotech DN-101 Water Quality Analysis Do Probe Industrial Cheap Online Dissolved Oxygen Sensor Meter Probe
OEM Manual Stainless Steel Online Industrial Sensor Dissolved Oxygen Electrode Do Probe
Rk500-04c Anti-Corrosion Dissolved Oxygen Do Sensor Probe for Fish Farming/Aquaculture
Oxygen Analyzer Molten Steel Temperature and Oxygen Probe
Expendable Compound Sublance Probe Tso Temperature Oxygen Measurement and Sampling
Disposable SpO2 Sensoring 7pin Adult Oxygen Probe Compatible with Nellcor
Sourcing guidance for Oxygen Probe
What are the key technical specifications to consider when selecting an oxygen probe for industrial use?
When sourcing oxygen probes, you must prioritize sensor type (e.g., Zirconia for high-temp combustion or Electrochemical for ambient monitoring). Key specs include a response time (T90) of <10 seconds, an accuracy range of ±1%, and operating temperature limits that match your specific environment. For combustion control, ensure the probe has integrated heating elements to maintain stable sensor temperatures.
Which compliance standards and certifications are mandatory for oxygen probes in global markets?
For hazardous environments, probes must carry ATEX or IECEx certifications for explosion-proof safety. In the US market, UL or FM approvals are standard, while the EU requires CE marking and compliance with the RoHS Directive to ensure no hazardous substances are used. If used in medical or food processing, look for FDA-compliant materials or ISO 13485 quality management systems.
How can I evaluate the durability and maintenance requirements of an oxygen probe?
Focus on the housing material, typically 316L Stainless Steel or Hastelloy for corrosive environments. Inquire about the sensor lifespan, which usually ranges from 12 to 24 months depending on gas concentration exposure. A high-quality probe should offer in-situ calibration capabilities to reduce downtime and a modular design that allows for easy replacement of the sensor cell without replacing the entire unit.
What integration capabilities should a modern B2B oxygen probe offer?
The probe should support standard industrial communication protocols such as 4-20mA analog output, RS485 Modbus RTU, or HART protocol for seamless integration into PLC and SCADA systems. Ensure the supplier provides digital signal processing to minimize electromagnetic interference (EMI) in heavy industrial settings.
Cross-Border Procurement & Risk Management for Oxygen Probes
What are the primary risks when importing high-precision sensors like oxygen probes?
The main risks include damage during transit affecting calibration and customs delays due to missing technical documentation. To mitigate this, insist on protective anti-static packaging and ensure the supplier provides a Certificate of Calibration and a detailed HS Code classification (typically 9027.10) to avoid tariff disputes.
How should I negotiate with suppliers on Made-in-China.com for bulk orders?
Start by requesting a sample for technical validation before committing to a large volume. Negotiate based on Total Cost of Ownership (TCO), including the cost of replacement sensors over 5 years. Aim for a tiered pricing structure where discounts of 10-20% are applied when reaching milestones like 50 or 100 units, and request a minimum 12-month warranty.
What transaction security measures should be taken for international payments?
Always use Secured Trading Services provided by platforms like Made-in-China.com to ensure payment is only released upon confirmation of shipment. For large enterprise orders, consider using a Letter of Credit (L/C) or Telegraphic Transfer (T/T) with a 30% deposit and 70% balance paid after a successful third-party pre-shipment inspection.
What is the best shipping method for sensitive electronic probes to ensure accuracy?
For high-precision instruments, Air Freight (DAP or CPT) is preferred over sea freight to minimize exposure to humidity and prolonged vibration. Ensure the shipping terms include Insurance coverage for the full invoice value. Request that the carrier uses 'Fragile' and 'Sensitive Instrument' labeling on all outer crates.