Co2 heater regulator
I have found results from1000+products and300+suppliers aboutCo2 heater regulator
Advanced CO2 Regulator with Built-in Heater and Flowmeter
Versatile CO2 Gas Regulator with Accurate Flow Control and Heater Features
User-Friendly CO2 Gas Regulator with Efficient Heater and Flow Control
Brass Body CO2 Gas Regulator with Heater and Flowmeter System
Quality CO2 Gas Regulator with Built-in Heater and Flow Measurement
Heavy-Duty CO2 Heater Regulator with Accurate Flowmeter for Welding
High Quality Brass CO2 Heater Regulator Flowmeter
Uweld High Quality Portable Industrial CO2 Heater Regulator Welding Cutting Tools
Uweld High Quality Portable Industrial CO2 Heater Regulator Welding Cutting Tools
Industrial CO2 Flowmeter Regulator with Heater (2W16-1024)
Industrial CO2 Flowmeter Regulator with Heater (2W16-1025)
Industrial CO2 Flowmeter Regulator with Heater (2W16-1026)
Heater for CO2 Pressure Regulator with Electric Wire (2W16-1036)
Brass Body CO2 Industrial Gas Flowmeters Regulator with Electrical Gas Heater
Ccsda K16 PRO Climate Regulator with 0.1℃ High Precision Display Accuracy
Future80 Power Failure Reminder Climate Regulator for Commercial Chicken Houses
K16 Multi-Sensor Climate Regulator with CO2, Nh3 & H2s Monitoring
Electrically Flowmeter Regulator with Heater for CO2
Aluminum Type CO2 Heater Regulator Flowmeter 36V/220V
Future80 Intelligent Livestock Barn Environment Regulator
Future80 Smart Ventilation Livestock Climate Regulator
Sourcing guidance for Co2 Heater Regulator
What are the key technical specifications to consider when selecting a CO2 heater regulator for industrial use?
When sourcing a CO2 heater regulator, you must prioritize heating capacity (measured in Watts) and flow rate stability. Ensure the heater is rated for at least 150W to 200W to prevent regulator freeze-up during high-flow applications. The input pressure rating should typically handle up to 15MPa (2175 PSI), and the output pressure should be easily adjustable with a clear dual-gauge display for both cylinder pressure and flow rate.
Why is the heating element critical in a CO2 regulator, and what safety features are required?
CO2 undergoes significant cooling when expanding from high to low pressure (the Joule-Thomson effect). A built-in electric heater is essential to prevent the internal components from icing, which can lead to gas flow blockage or seal failure. Look for units with automatic thermal overload protection and CE or UL certification for the electrical components to ensure the device shuts off if it exceeds safe temperature limits.
What material standards and connection types should B2B buyers verify?
The body should be constructed from forged brass or high-quality chrome-plated zinc alloy for maximum durability and corrosion resistance. Verify the inlet connection standard based on the destination country (e.g., CGA320 for North America, W21.8 for Europe/Asia, or G5/8). Ensure the sealing washers are made of high-density polymers like PTFE (Teflon) to prevent leaks under high pressure.
How does the voltage requirement impact international sourcing for these regulators?
Since these regulators require an external power source for the heater, you must match the voltage and plug type to the local grid. Common options include 110V (US/Japan) and 220V (Europe/China/Southeast Asia). Always confirm with the supplier if they provide customized plug configurations to avoid the need for dangerous adapters in industrial environments.
Cross-Border Procurement & Risk Management for CO2 Regulators
What are the primary risks when importing pressurized gas equipment from overseas?
The main risks include non-compliance with local pressure vessel regulations and electrical safety failures. To mitigate this, request third-party inspection reports (such as SGS or TUV) before shipment. Ensure the supplier on Made-in-China.com is a 'Diamond Member' or 'Audited Supplier' to verify their manufacturing legitimacy and quality control systems.
How should buyers negotiate quality assurance and warranty terms with suppliers?
Negotiate a minimum 12-month warranty specifically covering the heating element and the diaphragm. For bulk orders, request a 1-2% spare parts allowance (including extra washers and fuses) to be included at no extra cost. Use Trade Resources or Secure Payment services on the sourcing platform to ensure funds are only released upon confirmation of product specifications.
What are the best practices for shipping and logistics for sensitive calibration instruments?
Regulators contain sensitive gauges that can be damaged by vibration. Insist on double-layered corrugated box packaging with custom-fit EPE foam inserts. For shipping to international markets, use FOB (Free On Board) terms if you have a reliable freight forwarder, or DDP (Delivered Duty Paid) if you want the supplier to handle all customs clearances and import duties.
How can I verify the authenticity of certifications provided by the manufacturer?
Always ask for the certificate number and the name of the issuing body. Cross-reference these on the official websites of the certification agencies (e.g., the CE database or ISO registry). Reliable suppliers on Made-in-China.com will proactively upload these documents to their company profile for transparency.