Ups for elevator
I have found results from30000+products and8000+suppliers aboutUps for elevator
Double Conversion Online UPS 1-3kVA 900W 1800W 2700W with Long Backup Time Power for Elevator
2024 New UPS Power Supply System DC AC Delta Online UPS 1.5kVA 900W for Elevators
Three Phase Low-Frequency Online Uninterruptible Power Supply LCD Intelligent Dual Conversion 380V/400V 300kVA/240kw UPS for Elevators
Medical 10kVA 15kVA 20kVA Three 3 Phase Online UPS 8kw 16kw 24kw Uninterruptible Backup Power Supply for Elevator
Santak Modular UPS 25kVA-800kVA Online UPS for Elevator
220V/380V Industrial UPS 120kVA 3 Phase UPS for Elevators Online UPS Backup Power Supply
Hospital Elevator Critical environment 10kVA 20kVA 30kVA Industrial UPS Customised
OEM Low Frequency 3phases 380VAC 400VAC 415VAC 10kVA 20kVA 30kVA Elevator UPS
3 Phases PF1.0 10kVA 20kVA 30kVA UPS Online Double Conversion Elevator UPS
Low Frequency 3p 380VAC 10kVA 20kVA 30kVA 40kVA UPS for Elevators
Elevator Industrial Euipments 3 Three Phase in 3 Phase Output 100kVA 160kVA 200kVA 300kVA 400kVA 600kVA Online UPS
Elevator Industrial Euipments 3 Three Phase in 1 One Phase Output 6 Online UPS 6kVA 10kVA 20kVA 30kVA 40kVA 50kVA
Elevator Industrial Euipments 3 Three Phase in 1 One Phase Output Online UPS 40kVA 50kVA
Elevator Industrial Euipments Output 6 Online UPS 50kVA
UPS 60kVA Single Phase Online Elevator UPS Best 100kVA Uninterruptible Power Supply UPS
40/50/60kVA External Battery Long Backup Low Frequency 3 Phase Static and Manual Bypass Online Elevator UPS
Eaton 9ehd-31 UPS Power Supply Low Frequency Online 160kVA/144kw with DSP Tech for Laser Cutting Machine and Elevators
Elevator Power Outage Leveling Inverter UPS 10A 20A 24V 1000W Brand New
Industrial Frequency Online UPS 10kVA for Elevators
Sine Wave Online UPS 3 Phase in 3 Phase Output 20kv 60kVA 80kVA Online UPS for Elevator
Portable Power Supply UPS for Medical Machine and Elevator
LCD Display 6 to 20kVA Pure Sine Wave High Frequency Online UPS for Elevator Escape
10kVA to 200kVA with DSP Technology Three Phase Low Frequency Online UPS for Elevator
20kVA, 30kVA, 60kVA, 80kVA Online 3phase UPS with 1hour Backup Time for Elevator Escape System
Acmg Series Regenerative Modular Industrial UPS Bidirectional Energy Management for Elevator Machine
Vertiv Liebert Exs External Battery Three Phase Power Online UPS 40kVA for Elevators
Vertiv Liebert Hipulse U Industrial UPS Uninterruptible Power Supply 80kVA UPS for Elevators
Sourcing guidance for Ups For Elevator
What are the key technical specifications to consider when selecting a UPS for elevator systems?
When sourcing a UPS for elevators, the most critical factor is the Power Rating (kVA/kW), which must match or exceed the elevator motor's starting current. You should prioritize units with High Overload Capacity (typically 150% for 30 seconds) to handle the initial surge. Additionally, ensure the device features Pure Sine Wave Output to protect sensitive elevator control boards and integrated Automatic Rescue Device (ARD) functionality, which ensures the cabin reaches the nearest floor during a power failure.
Which battery technologies are most suitable for elevator UPS applications?
For long-term reliability, Lead-Acid (VRLA) Maintenance-Free batteries are the industry standard due to their cost-effectiveness and stability. However, for modern high-rise installations, Lithium Iron Phosphate (LiFePO4) batteries are becoming preferred because of their longer cycle life (2000+ cycles), smaller footprint, and faster charging capabilities. Ensure the battery management system (BMS) is compatible with the elevator's emergency braking system.
What international compliance standards must an elevator UPS meet?
Safety is paramount in elevator components. Ensure the supplier provides CE Certification for European markets or UL 1778 for North America. Specifically for elevators, look for compliance with EN 81-20/50 standards, which govern the design and safety requirements for lifts. Furthermore, the enclosure should have an IP20 or higher rating to protect against dust in machine rooms, and the unit must pass EMC (Electromagnetic Compatibility) testing to avoid interfering with lift sensors.
How does the environment of the elevator machine room affect UPS selection?
Elevator machine rooms often experience high temperatures and dust. You must select a UPS with a Wide Input Voltage Range to handle unstable power grids and an Operating Temperature Range of 0°C to 45°C. If the machine room lacks air conditioning, ensure the UPS has Intelligent Forced Air Cooling and a robust heat sink design to prevent thermal shutdown during emergency operations.
Cross-Border Procurement Strategy for Elevator UPS
How can I mitigate the risks associated with shipping heavy batteries internationally?
Batteries are classified as Dangerous Goods (Class 9). To ensure smooth transit, verify that the supplier provides a UN38.3 Test Report and an MSDS (Material Safety Data Sheet). For large-scale orders, using Sea Freight with specialized DG (Dangerous Goods) containers is the most economical and compliant method. Always confirm that the packaging meets IATA/IMDG standards to avoid customs seizures or fines.
What strategies should be used when negotiating with UPS suppliers on Made-in-China.com?
Focus on Technical Customization rather than just price. Ask for a Component List (e.g., brand of IGBTs and capacitors) to ensure quality. Request a Sample Test Report for the specific elevator motor power you intend to support. Negotiate for a 2-3 year warranty period and ask if they can provide spare PCBA boards as part of the bulk package to reduce future maintenance downtime.
How do I ensure transaction security and product quality during the sourcing process?
Utilize the Secured Trading Services offered by Made-in-China.com to protect your payment until delivery. Before final shipment, hire a Third-Party Inspection service (like SGS or Intertek) to perform a Full Load Test and verify the Automatic Switch-over Time (which should be <10ms). This prevents the receipt of units that might fail under the heavy inductive load of an elevator motor.
What are the common pitfalls in international trade policies for power electronics?
Be aware of Anti-Dumping Duties or specific Import Tariffs on power electronics in your country. Check the HS Code (typically 850440) against your local customs schedule. Ensure the supplier provides a Certificate of Origin (CO), such as Form E or Form F, which can significantly reduce or exempt import duties under various Free Trade Agreements.